Resource metadata

Field Value
Data last updated June 16, 2021
Metadata last updated March 16, 2021
Created March 16, 2021
Format XLSX
License CC-BY-NC-SA-4.0
Data collection infoDaily water level data were collected with a HOBO U20 water level data logger.  The water level is determined by continuously collecting the absolute pressure of the water column above a sensor, compensating it for atmospheric pressure, and calibrating it with reference water levels that are collected manually. The atmospheric pressure is measured by a HOBO U20 level logger (0- 4m range) that is installed in the airspace at the top of the wellhead. Manual water level level measurements were collected using either a Heron or Solinst water level tape (sounding tape).
Data processingData compensation and water level referencing were completed using HOBOWare Pro software. For the conversion of pressure to water level, the water density of freshwater is adjusted for water temperature. Pressures are converted to water level based on manual water level readings using a water level tape. The pressure data were reviewed to ensure they are within the factory calibrated range of the sensor. Water level time series and the manual and logger data were compared to identify any gross errors or potential instrument drift. Data collected prior to 2017-05-30 were not verified. Data from 2018-04-16 to 2018-05-07 were shifted to match the time series trends and account for instrument errors.
Data typelab
Datastore activeFalse
Datastore contains all records of source fileFalse
Has viewsTrue
Hash664be67e6e2e70f2917657af2cc07145
Header row1
Ida42a793d-0a1c-4a8d-a126-3bab6870f925
Mimetypeapplication/vnd.openxmlformats-officedocument.spreadsheetml.sheet
Package idb90f4bf2-9a3f-464c-afcf-eae77e433335
Position0
Resource citationLiving Lakes Canada Upper Columbia Basin Groundwater Monitoring Program. (2021) Groundwater (2013-10-12 to 2021-03-10) LLC VOW 01. Columbia Basin Water Hub. (Resource) Invermere. (DOI).
Resource data disclaimerNo warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose themselves.
Resource locationDistrict of Invermere; Althamer near wastewater treatment plant
Size819 KiB
Stateactive
Url typeupload
Waterhub certifiedCertified
Waterhub gradeTechnical Research Grade
Citation (Required) Living Lakes Canada Upper Columbia Basin Groundwater Monitoring Program. (2021) Groundwater (2013-10-12 to 2021-03-10) LLC VOW 01. Columbia Basin Water Hub. (Resource) Invermere. (DOI).
Resource Location District of Invermere; Althamer near wastewater treatment plant
Data Collection Information Daily water level data were collected with a HOBO U20 water level data logger.  The water level is determined by continuously collecting the absolute pressure of the water column above a sensor, compensating it for atmospheric pressure, and calibrating it with reference water levels that are collected manually. The atmospheric pressure is measured by a HOBO U20 level logger (0- 4m range) that is installed in the airspace at the top of the wellhead. Manual water level level measurements were collected using either a Heron or Solinst water level tape (sounding tape).
Data Processing Data compensation and water level referencing were completed using HOBOWare Pro software. For the conversion of pressure to water level, the water density of freshwater is adjusted for water temperature. Pressures are converted to water level based on manual water level readings using a water level tape. The pressure data were reviewed to ensure they are within the factory calibrated range of the sensor. Water level time series and the manual and logger data were compared to identify any gross errors or potential instrument drift. Data collected prior to 2017-05-30 were not verified. Data from 2018-04-16 to 2018-05-07 were shifted to match the time series trends and account for instrument errors.
Data Disclaimer No warranty or guarantee exists that the information is accurate, complete, current, or suitable for any purpose. The individual user must confirm the accuracy of the data and whether it will be appropriate for their purpose themselves.
Water Hub Data Grade Technical Research Grade
Date of Most Recent Water Hub QA/QC
Data type Laboratory Results

Site

No data available

Parameter

No data available